Bradford-white DS1-50S6FSX User Manual

Browse online or download User Manual for Water boiler Bradford-white DS1-50S6FSX. Bradford White DS1-50S6FSX User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
238-45839-00C REV 11/06
DIRECT VENT GAS WATER HEATER
A Spanish language version of these instructions is available by contacting
company listed on the rating plate.
La version espanola de estas instrucciones se puede obtener al escribirle a
la fabrica cuyo nombre aparece en la placa de especificaciones.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
For your safety and convenience, we recommend this water
heater be installed and serviced by a plumbing professional.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable,
combustible, or corrosive vapors and liquids in the
vicinity of this or any other appliance.
INSTALLATION & OPERATING
INSTRUCTION MANUAL
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
A
Spanish language version of these instructions is available by
contacting the company listed on the rating plate.
La versión espãnola de estas instrucciones se puede obtener al
escribirle a la fábrica
cuyo nombre aparece en la placa de
especificaciones.
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - DIRECT VENT GAS WATER HEATER

238-45839-00C REV 11/06 DIRECT VENT GAS WATER HEATER A Spanish language version of these instructions is available by contacting company listed on t

Page 2 - CONGRATULATIONS!

10 Installation continued- Figure 2 Figure 3

Page 3 - TABLE OF CONTENTS

11 Installation continued- VENTING This is a Direct Vent Gas Water Heater where all air for combustion is obtained from the outside atmosphere and al

Page 4 - GENERAL INFORMATION

12 Venting continued- Canadian Installations1 US Installations2 I= Clearance to service regulator vent outlet or oil tank vent 36 inches (91 cm)

Page 5 - INSTALLATION

13 Installation (Venting) continued- The co-axial vent-air intake tubes of this water heater can be installed in any 360° configuration as long as th

Page 6

14 Installation (Horizontal and Vertical Vent-Air Intake Lengths) continued- The water heater is shipped with the following standard vent and air int

Page 7

15 Installation (Horizontal and Vertical Vent-Air Intake Lengths) continued- Figure 6

Page 8

16 Installation continued- VENT-AIR INTAKE SYSTEM INSTALLATION WARNING The vent-air intake system must be properly installed. Failure to properly i

Page 9 - Figure 1

17 Installation (Vent-Air Intake System Installation) continued- 1. Measure the vertical height “Y” required in your installation. (See Figure 6).

Page 10 - Installation continued

18 Installation (Vent-Air Intake System Installation) continued- 5. Insert the straight end of the three (3) inch (7.6 cm) diameter elbow into

Page 11 - Figure 4

19 Installation (Vent-Air Intake System Installation) continued- Figure 9 7. Extend the three (3) inch (7.6 cm) diameter telescopic tube to its

Page 12 - Venting continued

2 CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today! This installation, operation and instruction manual

Page 13 - Figure 5

20 Installation (Vent-Air Intake System Installation) continued- Figure 10 8. Extend the five (5) inch (12.7 cm) diameter telescopic tube to its m

Page 14

21 Installation (Vent-Air Intake System Installation) continued- 9. From outside the building, slide the five (5) inch (12.7 cm) diameter telescopic

Page 15

22 Installation (Vent-Air Intake System Installation) continued- Figure 13 11. From inside the building, slide the backing plate over the five (5)

Page 16 - IMPORTANT

23 Installation (Vent-Air Intake System Installation) continued- 12. Mark the mounting screw hole locations for the backing plate. Rotate the backi

Page 17 - Figure 7

24 Installation continued- WATER CONNECTIONS Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off t

Page 18 - Figure 8

25 WARNING For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local

Page 19 - Figure 9

26 Installation (Water Connections) continued- WARNING FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4” X 3/4” TEMPERATURE AND PRESSURE REL

Page 20 - Figure 11

27 Installation (Water Connections) continued-

Page 21 - Figure 12

28 Gas Connections The gas supply lines must meet all requirements of the National Fuel Gas Code (ANSI Z223.1-Latest Edition), or in Canada CAN/CGA B

Page 22 - Figure 14

29 GENERAL OPERATION WARNING Water heaters are heat producing appliances. To avoid damage or injury, do not store materials against the water heate

Page 23 - Figure 15

3 TABLE OF CONTENTS page GENERAL INFORMATION... 4 INSTALLATION Locating The Water Heater

Page 24 - WATER CONNECTIONS

30 General Operation (Lighting Instructions) continued-

Page 25 - WARNING

31 THERMOSTAT ADJUSTMENT 160°F Control 180°F Control Figure 16 The thermostat dial is set to its low

Page 26 - plumbing supplier. Please

32 General Operation continued- Hotter water increases the risk of scald injury. Scalding may occur within five (5) seconds at a temperature setting

Page 27

33 MAINTENANCE WARNING Water heaters are heat producing appliances. To avoid damage or injury, do not store materials against the water heater or ve

Page 28 - CAUTION

34 Maintenance continued- 6. Annually remove the inner door and main burner assembly to clean orifices and related parts of any dirt or other foreig

Page 29 - GENERAL OPERATION

35 Maintenance continued- CAUTION FOR YOUR SAFETY, DO NOT ATTEMPT REPAIR OF COMBINATION GAS CONTROL, BURNERS OR GAS PIPING. REFER REPAIRS TO A QU

Page 30

36 PART NAME & DESCRIPTION 1. Direct Vent-Air Intake Terminal 21. Piezo Ignitor Assembly 2. Outer Wall Mount Plate 22. Drain Valve 3. Backi

Page 31 - THERMOSTAT ADJUSTMENT

37 DIRECT VENT WATER HEATER

Page 32 - Figure 18

38 VENT-AIR INTAKE KITS

Page 33 - MAINTENANCE

39 THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING 1. All piping compo

Page 34

4 GENERAL INFORMATION This gas-fired water heater’s design is certified by CSA International under the American National Standard Z21.10.1 - (as indi

Page 35

40 NOTES

Page 36 - PART NAME & DESCRIPTION

5 General Information continued- IMPORTANT Before proceeding, please inspect the water heater and its components for possible damage. DO NOT instal

Page 37 - DIRECT VENT WATER HEATER

6 Installation (Locating The Water Heater) continued- Water heaters in residential garages must be installed and located, or protected, to avoid phys

Page 38 - VENT-AIR INTAKE KITS

7 Installation (Locating The Water Heater) continued- WARNING Liquefied petroleum gases/propane gas are heavier than air and will remain at floor le

Page 39

8 Installation (Locating The Water Heater) continued- The water heater must be located close enough to the outside wall to keep the venting distance

Page 40

9 Installation (Minimum Clearances) continued- OPTIONAL DIRECT VENT-AIR INTAKE TERMINAL GUARD WARNING The direct vent-air intake terminal is HOT whi