238-44219-00J REV 6/09 A Spanish language version of these instructions is available by contacting the company listed on the rating plate. La versio
10VENTING This water heater has been shipped with a draft diverter for which it was designed with reference to the horizontal and vertical planes.
11Venting continued- This water heater must be connected to a lined masonry chimney or venting system approved by local codes or ordinances. The ve
12Combustion Air Supply continued- Confined Spaces Confined spaces are spaces defined as having less than 50 ft.3 of space per 1,000 BTU (1.41m3/.29
13WATER CONNECTIONS Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, ope
14Installation (Water Connections) continued- WARNING For protection against excessive temperatures and pressure, install temperature and pressure p
15Installation (Water Connections) continued- This water heater can deliver scalding temperature water at any faucet in the system. Be careful whe
16Gas Connections The gas supply lines must meet all requirements of the National Fuel Gas Code (ANSI Z223.1-Latest Edition), or in Canada CAN/CGA B
17GENERAL OPERATION TO FILL THE WATER HEATER 1. Close the water heater drain valve by turning the knob clockwise . 2. Open the cold water supply
18Lighting and Shutdown Instructions-White Rodgers and Robertshaw gas control.
19Lighting and Shutdown Instructions-Honeywell gas control.
2 CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today! This installation, operation and instruction manual
20THERMOSTAT ADJUSTMENT - White Rodgers gas control. 160°F Control 180°F Control Figure 2 T
21THERMOSTAT ADJUSTMENT - Honeywell gas control. 160°F (71.1°C) Control Figure 4 The thermostat dial is set to its lowest temperature set
22 General Operation continued- Hotter water increases the risk of scald injury. Scalding may occur within five (5) seconds at a temperature setti
23MAINTENANCE The following maintenance should be performed by a qualified service technician at the minimum periodic intervals suggested below. I
24Maintenance continued- 6. At least once a year, check the combination temperature and pressure relief valve to insure that the valve has not beco
25Maintenance continued- Contact your supplier or plumbing professional for replacement parts or contact the company at the address given on the ra
26TROUBLESHOOTING CHART LED Status Control Status Probable Cause None (LED not on or flashing) Millivolt power is not present. Light pilot. 1. Ga
27TROUBLESHOOTING CHART (CONTINUED) LED Status Control Status Probable Cause Six flashes and three second pause. Water leak detected by accessory
28INSTALLATION FOR POTABLE WATER Figure 7
29PARTS LIST DRAWING
3 TABLE OF CONTENTS page GENERAL INFORMATION... 4 INSTALLATION ...
30PARTS LIST PART NAME AND DESCRIPTION 1. Draft Diverter 14. Drain Valve 2. Jacket Head Pan 15. Piezo Igniter 3. Jacket 16. Gas Valve 4. Outer D
31THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING 1. All piping compone
32NOTES
4GENERAL INFORMATION This gas-fired water heater is design certified by CSA International under the applicable American National Standard, Z21.10.1
5General Information continued- This water heater has been manufactured for operation at altitudes from sea level to 2000 feet (610m) (unless otherw
6INSTALLATION LOCATING THE WATER HEATER This water heater MUST NOT be installed in any location where gasoline or flammable vapors are likely to b
7Installation (Locating The Water Heater) continued- Note: For California installation this water heater must be braced, anchored, or strapped to av
8Installation (Locating The Water Heater) continued- Proper venting practices must be considered when selecting a location for this water heater. F
9 MINIMUM CLEARANCES WARNING Failure to adhere to these installation and operating instructions may create a hazard to life and property and will nu