28
TROUBLESHOOTING
LED St at u
Control Statu
Probable Cause
None (LED not on
or flashin
Elect rical pow er not
resent
Control power sw itch in " OFF" position.
Su
l
volta
e interru
ted.
One short flash
every f our
seconds
Stand-by mode,
Thermost at is satisf ied (no
faults
Temperature demand is satisfied (no call for
heat )
Alternates bright
and dim
heart beat
Thermost at calling f or heat
(no fault)
Tank temperature below setpoint of
thermost at
Short flash once
every second
Weak pilot signal on last
call for heat
1. Unstable pilot
2. Pilot tube blocked or restricted
3. Oxidation build-up on pilot electrode
4. Wire damage to pilot assembly or bad
connection at gas valve
Tw o flashes,
three second
pause
Damper test circuit not
working
1. Damper not in proper position or
malfunctioning - stuck in open position
2. Obstructed venting
3. Fault
damper
Three f lashes,
three second
pause
Damper test circuit not
working
1. Damper not in proper position or
malfunctioning - not reaching full open
position
2. Obstructed venting
3. Faulty damper
Four flashes,
three second
ause
Excessive tank
temperature, system must
be reset
1. Thermal w ell sensor out of calibration
2. Faulty gas valve
Five f lashes,
three second
ause
False pilot flame present Pilot valve stuck in open position
Six flashes, one
flash, t hree
second pause
(Soft Lockout)
Failed to light pilot,
syst em resets after (5)
minutes
1. Unstable pilot
2. Pilot tube block or restricted
3. Oxidation build-up on pilot electrode
4. Wire damage to pilot assembly or bad
connection at gas valve