Troubleshooting continued-
LED St at u
s
Control Statu
s
Probable Cause
Six flashes, two
flashes, t hree
second pause
(Soft Lockout)
Damper test circuit not
w orking properly during
burner operation, system
auto resets after (5)
minutes
1. Damper not in proper position or
malfunctioning - damper moved from full
open position during run cycle
2. Obstructed venting
3. Faulty damper
4. Damper jostled during run cycle
Six f lashes, t hree
flashes, t hree
second pause
(Soft Lockout)
Pilot flame extinguished,
system auto resets after
(5) minutes
1. Unstable pilot
2. Pilot tube block or restricted
3. Oxidation build-up on pilot electrode
4. Wire damage to pilot assembly or bad
connection at gas valve
5. Insufficient combustion air
Six flashes, four
flashes, t hree
second
p
ause
Undesired false pilot flame
sensed, syst em auto
resets
Pilot valve stuck in open position
Seven flashes,
three second
pause
Flammable vapor sensor or
resettable thermal switch
fault detected, see
w arning label
1. Flammable vapor present
2. Flammable vapor sensor exposed to
excessive moisture
3. Flammable vapor sensor exposed to
extreme ambient temperat ure
4. Resettable thermal switch open
Eight flashes, one
flash, t hree
second pause
Flammable vapor sensor
out of specification,
possible short
1. Flammable vapor sensor out of
specification
2. Possible short in flammable vapor sensor
or resettable thermal sw itch w iring
Eight flashes,
three f lashes,
three second
pause
Thermal well sensor
damaged or unplugged or
gas valve electronics fault
detected
1. Damage to thermal well w ires
2. Thermal w ell sensor resistance out of
range
3. Replace t hermal w ell
4. Verify control is not w et or physically
damaged
5. Reset control on/off switch
6. Replace electronic module if 8-3 error
persists
Eight flashes, four
flashes, t hree
second pause
Gas valve fault detected
1. Verify control is not w et or physically
damaged
2. Reset control on/off switch
3. Replace gas control if 8-4 error persists
Fault Probable Cause
Resettable Thermal Switch Tripped (Open) 1. Insufficient combustion air
2. Flammable vapor present